Uploaded by dturner LT Scope, vapor deposit 1 day RT , 8-mercapto-1-octanol on Au(111), RT, 1.0 mM in ACN, water on, beam=-1.15 kV, 1 minute H exposure
Uploaded by dturner
Created: March 28, 2019
Updated: March 28, 2019
Uploaded by jpetersen HOPG Clean Check
Uploaded by jpetersen
Created: April 2, 2019
Updated: April 2, 2019
Uploaded by dturner LT Scope, Au(111) setpoint = 200 pA gain = 1.0, Faraday cage on pre-amp, line time = 500 ms, lots of noise
Uploaded by dturner
Created: April 4, 2019
Updated: April 4, 2019
Uploaded by dturner LT Scope, vapor deposit 1 day RT, 8-mercapto-1-octanol on Au(111), 10 mM in ACN, water on, beam = -1.10 kV, 31 minutes H exposure
Uploaded by dturner
Created: April 8, 2019
Updated: April 8, 2019
Uploaded by cschalk LT Scope, vapor deposit 5 day RT, 8-mercapto-1-octanol on Au(111), 10 mM in ACN, water on, beam = -1.10 kV, 31 minutes H exposure
Uploaded by cschalk
Created: April 9, 2019
Updated: April 9, 2019
Uploaded by asilski dibenzazepine pulse deposited on Au(111), 5 mM in MeOH, 1x1000us
Uploaded by asilski
Created: April 9, 2019
Updated: April 9, 2019
Uploaded by asilski dibenzazepine pulse deposited on Au(111), 5mM in MeOH, 1x1000us
Uploaded by asilski
Created: April 10, 2019
Updated: April 10, 2019
Uploaded by dturner LT Scope, vapor deposit 5 day RT, 8-mercapto-1-octanol on Au(111), 10 mM in ACN, day 2, 31 minutes H exposure
Uploaded by dturner
Created: April 10, 2019
Updated: April 10, 2019
Uploaded by cschalk LT Scope, vapor deposit 7 day RT, 8-mercapto-1-octanol on Au(111), 10 mM in ACN, water on, HV=1.1kV
Uploaded by cschalk
Created: April 11, 2019
Updated: April 11, 2019
Uploaded by dturner LT Scope, vapor deposit 8 day RT, 8-mercapto-1-octanol on Au(111), 10 mM in ACN, water on, beam = -1.1 kV, 2 minutes H exposure
Uploaded by dturner
Created: April 12, 2019
Updated: April 12, 2019
Uploaded by asilski ferrocenecarboxylic acid pulse deposited on Au(111), 10mM in benzene, 1x1000us
Uploaded by asilski
Created: April 12, 2019
Updated: April 12, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111), 5mM in acetonitrile, 2x1000us
Uploaded by asilski
Created: April 12, 2019
Updated: April 12, 2019
Uploaded by jpetersen Gold Bis(Acetylide), Tsui group compound, 10 mM THF, 3x1000us, Au(111)/Mica#3
Uploaded by jpetersen
Created: April 16, 2019
Updated: April 16, 2019
Uploaded by cschalk LT Scope, vapor deposit 8thiol Au(111), water on, beam = -1.1 kV, 2 minutes H exposure
Uploaded by cschalk
Created: April 17, 2019
Updated: April 17, 2019
Uploaded by jpetersen Gold Bis(acetylide), 10 mM in THF, 3x1000us, Au(111)/Mica#3
Uploaded by jpetersen
Created: April 17, 2019
Updated: April 17, 2019
Uploaded by jpetersen Gold Bis(acetylide), 10mM in THF, 3x1000us, Au(111)/Mica#3
Uploaded by jpetersen
Created: April 22, 2019
Updated: April 22, 2019
Uploaded by dturner LT Scope, vapor deposit 8thiol Au(111), water on, beam = -1.1 kV, 1 minute H exposure
Uploaded by dturner
Created: April 22, 2019
Updated: April 22, 2019
Uploaded by cschalk LT Scope, 12 day vapor deposit RT, 8thiol-OH on Au(111), 10 mM in ACN, water on, beam = -1.1 kV, 1 minute H exposure
Uploaded by cschalk
Created: April 23, 2019
Updated: April 23, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111), 11mM in ACN, followed by 45C 20 min anneal
Uploaded by asilski
Created: April 23, 2019
Updated: April 23, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111)#3, 11mM in ACN
Uploaded by asilski
Created: April 24, 2019
Updated: April 24, 2019