Uploaded by dturner LT Scope, 2 day vapor deposit RT, 8thiol-OH on Au(111), 10 mM in ACN, water on, kV=-1.1 kV, 7 minutes H exposure
Uploaded by dturner
Created: April 25, 2019
Updated: April 25, 2019
Uploaded by cschalk LT Scope, 5 day vapor deposit RT, 8thiol-OH on Au(111), 10 mM in ACN, water on, beam = -1.1 kV, 63 minutes H exposure
Uploaded by cschalk
Created: April 30, 2019
Updated: April 30, 2019
Uploaded by cschalk LT Scope, e-beam evaporated Au
Uploaded by cschalk
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by cschalk LT Scope, 7 day RT vapor deposited 8thiol-OH on Au(111), 10 mM in ACN, water on, beam = -1.1kV
Uploaded by cschalk
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by cschalk LT Scope, 7 day RT vapor deposited 8thiol-OH on Au(111), 10 mM in ACN, 20 minute H exposure with the tip completely out of the way
Uploaded by cschalk
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by dturner LT Scope, 8 day RT vapor deposited 8thiol-OH on Au(111), 10 mM in ACN, water on, beam = -1.1 kV
Uploaded by dturner
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by dturner LT Scope, 5 day RT vapor deposited 8thiol-OH on Au(111), 10 mM in ACN, 63 minute H exposure
Uploaded by dturner
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by jpetersen Au Bis(Acetylide), 10 mM in THF, 3x1000us, Au(111)/Mica#3
Uploaded by jpetersen
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by jpetersen Au Bis(Acetylide), 10 mM THF, 5x1000us, Au(111)/Mica#3
Uploaded by jpetersen
Created: May 2, 2019
Updated: May 2, 2019
Uploaded by jpetersen Au Bis(Acetylide), 10 mM THF, 5x1000us, Au(111)/Mica#3
Uploaded by jpetersen
Created: May 3, 2019
Updated: May 3, 2019
Uploaded by cschalk Peltier Scope, 5 day RT vapor deposited 8thiol-OH on Au(111), 10 mM in ACN
Uploaded by cschalk
Created: May 6, 2019
Updated: May 6, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111)#3, 10mM in ACN, 2x1000us
Uploaded by asilski
Created: May 6, 2019
Updated: May 6, 2019
Uploaded by dturner Cracker Scope, 5 day RT vapor deposited 8thiol-OH on Au(111), 10 mM in ACN, Peltier prescanned, 15 min H atom exposure, tip far retracted
Uploaded by dturner
Created: May 7, 2019
Updated: May 7, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111)#3, 10mM in ACN, 2x1000us
Uploaded by asilski
Created: May 7, 2019
Updated: May 7, 2019
Uploaded by cschalk Cracker Scope, vapor deposited 8thiol on Au(111)
Uploaded by cschalk
Created: May 8, 2019
Updated: May 8, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111), 10mM in MeOH, 1x1000us
Uploaded by asilski
Created: May 9, 2019
Updated: May 9, 2019
Uploaded by cschalk Cracker Scope, DAY 2 vapor deposited 8thiol on Au(111), 45 min exposure, 5 minutes at 10^-5 torr
Uploaded by cschalk
Created: May 9, 2019
Updated: May 9, 2019
Uploaded by asilski 6-bromoisatin pulse deposited on Au(111)#2, 10mM in MeOH, 3x1000us
Uploaded by asilski
Created: May 10, 2019
Updated: May 10, 2019
Uploaded by asilski 5-methylisatin pulse deposition 10mM MeOH, 2x1000us
Uploaded by asilski
Created: May 11, 2019
Updated: May 11, 2019
Uploaded by cschalk Cracker Scope, vapor deposited 8thiol on Au(111), beam on kV=-1.1, water on, ion gauge on, 5 minute H exposure at 10^-7 torr followed by 10 minutes H exposure at 10^-6 torr
Uploaded by cschalk
Created: May 13, 2019
Updated: May 13, 2019